GECOR Systems
for Corrosion Analysis of Concrete Steel Reinforcement Bars
GECOR 8- World's most advanced system for analyzing corrosion of concrete steel reinforcement bars.
Gecor
8 represents the latest technology in steel reinforcing
bar corrosion rate determination. It combines state of the art embedded
microprocessor systems and computerized flash technology with the
world's leading research in reinforcing bar corrosion rate analysis.
The
Gecor 8 features:
- A
method for rapidly mapping a structure's corrosion rate.
- An
advanced modulation confinement technique for precise corrosion
rate analysis.
- A
new corrosion rate analysis technique for use in very wet or submerged
structures.
- New
methodology for measurement of cathodic protection efficiency
and more…
The rapid mapping
technique of the Gecor 8 allows the engineer to quickly classify
areas of a structure while the unit's built-in programming can graphically
analyze this data and produce contour maps of suspected areas. And,
our advanced modulation confinement technique accurately measures
the true polarization resistance of the steel reinforcing bar.
Combined with
the latest advances in interface systems and database storage technology,
the Gecor 8 is an easy to use, reliable, automatic and intelligent
corrosion rate analysis system. A system that can save an engineer
time, money and effort in evaluating structures for subsequent rehabilitation.
Specifications
C-CS-8300: Complete
System
C-CS-8000C:
Basic System
• battery charger
• corrosion rate meter
• 30 meters cable
• sensor A Cu/CuS04
• sensor B Cu/CuS04
• verification box
C-CS-8000A: Basic System
• battery charger
• corrosion rate meter
• 30 meters cable
• sensor A Ag/AgCI
• sensor B Ag/AgCI
• verification box
C-CS-8100C: Submersion Upgrade
• sensor C Cu/CuS04
• corrosion rate meter
C-CS-8100A: Submersion Upgrade
• sensor C Ag/AgCI
• corrosion rate meter
C-CS-8200: Cathodic protection Upgrade
C-CS-8232: Database Software
Download
Leaflet
GECOR 6 - Measures
the rate of corrosion and other parameters of rebars.
The Gecor
6 utilizes the polarization resistance technique
to establish the corrosion rate. This is a quantitative measure
of the amount of steel oxidizing at the time of measurement. Up
to 100 readings can be stored in memory for later uploading to a
Personal Computer. Relative humidity, temperature, half-cell potentials
and concrete resistivity also can be measured. Weighing only nine
pounds, the system is easy to use, portable and menu driven.
Specifications
C-CS-5000:
Complete System
Battery: 4D (4 hours operation)
Memory: Up to 100 Corrosion
Rate Readings
Sensor A: Corrosion Rate, Corrosion Potential, Concrete Resistance,
Date, Time, Location of Reading
Sensor B: Concrete Resistivity, Relative Humidity, Temperature (°C)
Download
Leaflet
Concrete NDT Test Main Page
Building
Materials Testing Main Page
For
more information, or to request a quotation, please E-mail our sales
department at: sales@qualitest-inc.com,
or
call us toll-free at: 1-877-884-TEST.
|