QT-WVP-202 Water Vapor Permeability Tester is designed to test the water vapor transmission rate (WVTR) of a wide range of packaging materials such as plastic film, composite film, coextrusion film, aluminum-plated film, aluminum foil, infusion bag, sheets, solar panel, cellophane, ceramics, porcelain and various containers like bag, pouch, bottle, can, bowl, box, etc. that widely used in the industries of food, pharmaceuticals, personal care, household, electronics by electrolytic method.
It is the ideal water vapor permeability tester for R&D institutions, factories, universities with reliability, speed, versatility and accuracy that required for Quality Control testing.
ISO 15106-3 is the standard specifies an instrumental method for determining the water vapour transmission rate of plastic film, plastic sheeting and multi-layer structures including plastics, using an electrolytic detection sensor. The method provides rapid measurement over a wide range of water vapour transmission rates.
To test the water vapor transmission rate (WVTR) of packaging materials, such as plastic film, composite film, co-extrusion film, aluminum-plated film, aluminum foil, infusion bag, sheets, paper, paper board, solar battery panel, cellophane, ceramics and porcelain, and various containers such as bag, pouch, bottle, can, bowl, box, widely used in the industries of food, pharmaceuticals, personal care, household, electronics and so on.
Electrolytic detection sensor method. Test sample is fixed in the middle of test chamber to separate the chamber into upper room and lower room. When humid gas and dry gas flow in upper and lower room respectively, the water molecules in upper room will penetrate through the sample into the lower room, then electrolytic sensor system detect and analyze the water content to calculate the water vapor transmission rate.
Model |
QT-WVP-202 |
Test Range |
0.001~100 g/(m2 • 24h) (film and sheet) |
Test Precision |
0.001 g/(m2 • 24h) (film and sheet) |
Temperature Range |
15~45℃ (5~55℃ optional) |
Temperature Precision |
±0.1℃ |
Humidity Range |
Dryness: 0%RH, humidity: 30 to 90%RH, 100%RH |
Humidity Precision |
±1%RH |
Number of Samples |
1~2 pieces |
Test Area |
50.24cm2 |
Sample Size |
Φ100mm |
Sample thickness |
≤ 2mm |
Carrier Gas |
99.999% N2 (user provide) |
Carrier Gas Pressure |
≥ 0.1Mpa |
Nitrogen (N2) Purity Requirement |
Must be 99.999% |
Laboratory Temperature Requirement |
23 ± 2℃ (A 20m2 laboratory allows only one operator) |
Instrument Size |
610 × 550 × 400mm |
Weight |
80kg |
Power |
500W |
Standard Configuration |
|