Automatic Pensky-Martens Closed Cup Flash Point Tester - QualiFPT™-CC-Auto

The QualiFPT™-CC-Auto automatic Pensky-Martens flash point tester determines the closed cup flash point of fuels, lubricants, and other petroleum products according to ASTM D93. Refineries, fuel terminals, lubricant blenders, and independent laboratories use it to classify flammable liquids and verify product specifications. The instrument covers flash points from 40°C to 370°C, matching the full temperature range of the standard. Preset programs run Procedures A, B, and C, so one unit handles distillate fuels, residual oils, and biodiesel.

Testing starts with a single command once the operator loads the sample and enters the expected flash point. The tester then lowers the test head, stirs, heats, applies the ignition source, detects the flash, sounds an alarm, cools the cup, and prints the result. A micro thermocouple identifies the flash electronically, which removes the subjectivity of visual observation. A built-in pressure sensor corrects each result to standard atmospheric pressure, and the internal database stores up to 5,000 tests.

Qualitest supplies the QualiFPT™-CC-Auto with a complete accessory kit, including reference thermometers for three temperature bands, the test cup, and an LPG connection line. Electronic and gas ignition are both available, so each lab can follow its preferred setup. The compact benchtop footprint of 384 × 418 × 328 mm fits a standard laboratory bench. 

Request
Quotation

Related Articles

Displaying 1 - 3 of 3
Flash Point Tester Comparison: Manual vs Auto vs Rapid

Flash Point Tester Comparison: Manual vs Auto vs Rapid

Pinning down an exact flash point is what protects your entire production run from costly safety failures. Modern petroleum testing hardware gives laboratory managers complete flexibility to match instruments directly to daily sample volume and shift cadence. Selecting the right manual vs automatic vs rapid flash point tester setup keeps your daily numbers moving cleanly, locks in steady repeatability, and protects your capital budget from over
Petroleum Flammability Units: Open vs Closed Cup Guide

Petroleum Flammability Units: Open vs Closed Cup Guide

Could an unverified flammability test cost your facility an entire fuel cargo or trigger a severe regulatory penalty? Did you know that running the wrong apparatus can swing your recorded flash temperatures by tens of degrees simply because volatile vapors behave differently under a sealed cover versus open air? Evaluating flash point open cup vs closed cup methodologies protects your product certification, keeps testing shifts moving, and
Compare ASTM D93 vs D92 vs D56 Flash Point Methods

Compare ASTM D93 vs D92 vs D56 Flash Point Methods

Could an incorrect flash point method trigger regulatory penalties or misclassify your hazardous cargo? While ASTM D56, ASTM D92, and ASTM D93 dominate hydrocarbon quality control, each standard functions under distinct cup geometries, heating dynamics, and viscosity thresholds. Resolving the technical trade-offs among ASTM D93 vs D92 vs D56 protects product compliance while preventing costly analytical errors. Here is the operational breakdown