Capillary Rheometer Specifications
|
|
Model
|
Description
|
Options for Special Requirements
A comprehensive list of optional features provides for the testing of a wide range of materials. These include:
|
|
LCR7000
|
LCR7000 capillary rheometer with load cell, with cleaning and operating tools, and one tungsten carbide orifice.
|
Corrosion-resistant alloy barrel for testing corrosive materials such as PVC
Tungsten carbide dies with a broad range of diameters and L./D ratios provide a wide range of measurement capability
Laser micrometer for accurate measurements of die swell as the extrudate exits the die
|
|
LCR7001
|
LCR7001 capillary rheometer with load cell, barrel-mounted pressure transducer, and long barrel, includes cleaning and operating tools and three tungsten carbide orifices.
|
Corrosion-resistant alloy barrel for testing corrosive materials such as PVC
Tungsten carbide dies with a broad range of diameters and L./D ratios provide a wide range of measurement capability
A melt pressure transducer mounted just above the die, eliminates frictional and barrel pressure effects
Laser micrometer for accurate measurements of die swell as the extrudate exits the die
|
|
LCR7002
|
LCR7002 dual bore capillary rheometer with barrel-mounted pressure transducers, cleaning and operating tools, and four tungsten carbide dies
|
|
Capillary Rheometer - LCR 7000/LCR 7002 Specification
|
|
Barrel Length:
|
Barrel Diameter: 9.55 mm ±0.005 mm (0.3760 in. ±0.0002 in.) (LCR 7002 features dual barrel diameters)
|
|
Barrel Capacity:
|
approx 14ml
|
|
Drive System:
|
DC servo motor
|
|
Piston Speed:
|
0.03 to 600 mm/min
|
|
Dynamic Range:
|
20,000:1
|
|
Apparent Shear Rate with a 1mm Diameter Die:
|
0.4 to 7,296 s-1
|
|
Maximum Testing Force:
|
10 kN standard, 15 kN optional
|
|
Force Measurement Method:
|
LCR 7000: Load cell and barrel mounted pressure transducer supplied
|
|
LCR 7002:
|
Two barrel-mounted pressure transducers supplied
|
|
Dies:
|
Tungsten carbide capillary, many L/D ratios available
|
|
Die Swell Measurement:
|
Optional Laser Micrometer
|
|
Temperature Range:
|
430°C standard
|
|
Heating System:
|
Multi-zone electric heater
|
|
Temperature Measurement:
|
Platinum RTD 4-wire system
|
|
Temperature Control System:
|
Adaptive PID temperature control algorithm 0.1°C resolution
|
|
Temperature Control Accuracy:
|
±0.2°C at 13 mm
|
|
Temperature Distribution in Test Area:
|
<1% variation
|
|
Power Supply:
|
120/230 VAC 50/60 Hz ±10%
|
|
Power Consumption:
|
750 W maximum, 200 W typical
|
|
Data Processing System:
|
Personal computer based
|
|
System Software:
|
LAB KARS (Laboratory Advanced Rheology Software) For Windows™ Microsoft Excel based.
|