Lighting/measuring conditions | Reflection: d/8 (diffuse illumination, 8° direction reception) |
SCI (Contains specular reflected light)/ SCE (not contain specular reflected light) measure at same time. Compliance standards: CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7,JIS Z8722 Condition C, ASTM E1164, ASTM-D1003-07 |
Transmission: d/0 (diffuse illumination, vertical reception) |
| Differential spectrum engine |
| |
Integrating sphere diameter | |
| |
| |
Reflectance measurement range | |
| Pulsed xenon lamps and LED |
| Includes UV, 400nm cutoff, 420nm cutoff, 460nm cutoff |
| |
Lighting/measuring calibers | Reflection: XLAV Φ25.4mm/Φ30mm;LAVΦ15mm/Φ18mm;MAVΦ8mm/Φ11mm;SAVΦ3mm/Φ6mmUsers can customize the calibre, and the calibre switch is automatically recognizedTransmission:Φ17mm/Φ25mm |
Transmission measurement specification | Sample height and thickness: height is not limited, thickness ≤50mm |
| XLAV chroma value: standard deviation ΔE*ab 0.01 or less (under constant temperature conditions, the white correction plate is measured every hour within 24 hours) |
| ΔE*ab≤0.01, Spectral reflection/transmittance ≤0.1% | ΔE*ab≤0.005,Spectral reflection/transmittance ≤0.1% |
Inter-Instrument Agreement** | | | |
| |
| A, B, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, U35, DLF, NBF, TL83, TL84, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2 |
| | | |
| Spectral data, Spectrogram, chromaticity data, chromaticity Data, chromaticity map, Pass/Fail judgment, Simulation color, Color evaluation, fog, liquid chromaticity, Color bias |
| CIE LAB,CIE LUV, LCh, Hunter Lab, Yxy, XYZ, Musell, s-RGB, βxy |
| WI(ASTM E313-20, ASTM E313-73, CIE, ISO2470/R457, AATCC, Hunter, Taube, Berger Stensby), YI(ASTMD1925, ASTM E313-20, ASTM E313-73), Tint(ASTM E313-20), Isochromatic index Milm, color fastness, color changing fastness, ISO brightness, R457, A density, T density,E density, Mdensity, APHA/Hazen/Pt-Co(platinum-cobalt index),Gardner(Gardner Index), Saybolt(Seibert Index), Astm color, fog, total transmittance, covering power, force, intensity |
| ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc,ΔE*94,ΔE*00,ΔEab(Hunter),555 color tone classification |
| |
| 7-inch capacitive touch screen |
| |
| Dc regulated power supply |
Operating temperature and humidity | 5 ~ 40°C, relative humidity 80%(35°C) below no condensation |
Storage temperature and humidity | -20 ~ 45°C, relative humidity 80%(35°C) below no condensation |
| Power adapter, USB cable, transmission fixture, software U disk, black cavity, white board, greenboard,30mm aperture, 18mm aperture ,11mm aperture, 6mm aperture, support table, cuvette, |
| Heating transmission jig (including control circuit), vertical bracket, pneumatic jacking rod (including control circuit), small sample holding accessories, reflection cupping plate (non-removable), fiber test box, film jig, micro transmission jig, rod box, European standard plug, American standard plug |
| RS-232, USB, USB-B, Bluetooth |
| Ultra HD camera (1400dpi) |
| √ (Can greatly improve the long-term repeatability of the instrument) |
| √ (Can automatically adjust the UV intensity, and ensure that the value of the instrument is highly consistent with that of other imported instruments when measuring materials containing fluorescence) |
| √ (Through the brightness calibration algorithm, the real color of ultra-dark samples is restored) |
| The instrument can be measured sideways, up and down (using accessories); Automatic temperature and humidity compensation function; PC side software save sample image function |