Insertion-type Ultrasonic Flow Meter Parent Product Ultrasonic Flow Meter – Multi-channel Series Applications Theory/Method Insertion-type Ultrasonic Flow MeterInsertion-type Ultrasonic Flow Meter utilizes advanced intelligence and integrative mixed signal processing technology, resulting in high-precision measurements. With a specialized opening tool, the insertion transducer can be installed without shutting off the water flow. Since the transducer is in direct contact with the fluid, it ensures stable and reliable measurement. This ultrasonic flow meter is widely used in process control, production measurement, trade settlement, and other fields. It has seen extensive application in water supply and drainage, metallurgy, petrochemical industries, water resource management, and energy monitoring sectors.No need to shut off water during installationOne-channel, two-channel, and four-channel transducers availableMeasurement accuracy ranges from 0.5% to 1%, depending on the number of channelsCompatible with pipe diameters from DN50 to DN6000Large LCD display provides abundant informationOperates with fluid temperatures ranging from -30°C to 160°CDurable stainless steel transducers Can connect to three-wire or four-wire temperature transducers for heat/cooling energy measurement Insertion-type Ultrasonic Flow Meter ClassificationThe multi-channel insertion ultrasonic flow meter consists of a converter and insertion transducers. The converter and insertion transducers can be combined in various configurations, allowing for one-channel, two-channel, or four-channel flow measurement to accommodate different precision requirements and measurement scenarios. Optional ConvertersFixed mount converterWall mount converterModule converterExplosion proof converterPanel mount converter Optional TransducerOne-channel transducerTwo-channel transducerFour-channel transducer 1. Insertion-type Ultrasonic Flow Meter Wall mountThe converter can be mounted on walls or instrument boxesLarge LCD display provides abundant informationOne-channel, two-channel, and four-channel options availableNavigation menu with sixteen-digit key operationDurable die-cast aluminum converterEquipped with a stainless steel probe and probe column32 megabytes of memory, with optional USB mass storageCan connect to three-wire or four-wire Pt100 temperature transducers for heat/cooling energy measurement Working environment ConverterTransducerProtection classIP67IP68Humidity≤85%RHIP68Temperature-20~60℃-30℃~160℃Essential parameter One-channelTwo-channelFour-channelAccuracy±1%±0.5%±0.5%Flow rate≥0.3m/s≥0.3m/s≥0.1m/sPipe diameterDN50~DN6000mmLiquid temperature-30℃~160℃Type of liquidWater, sea water, sewage, Acid-alkali solution, ethyl alcohol, beer, single and even liquid which can transmit sound wave, such as oil, etc.Signal output1 way 4-20mA output, electric resistance 0-1K(DC24V power supply), accuracy 0.1%1 way OCT pulse output , pulse width 6-1000ms1 way relay output or frequency outputSignal input3 way 4-20mA input, can be a data collectorConnect three wire/four wire PT100 temperaturetransducer to realize heat/cooling energy measurementData interfaceInsulate RS485 serial interface, support the MODBUSPower supplyDC8-36V;AC10-30V;AC85-264V (110V also available)Installation dimension 2. Insertion-type Ultrasonic Flow Meter ModuleDIN-rail mounting for batch installation in instrument boxes or distribution cabinetsLarge LCD display provides abundant informationOne-channel option availableNavigation menu with four-digit key operationBuilt-in 32 megabytes of memory, capable of storing 2000 rows of dataEquipped with a stainless steel probe and probe columnSmall size and cost-effectiveCan connect to three-wire Pt100 temperature transducers for heat/cooling energy measurement Working environment ConverterTransducerProtection classIP30IP68Humidity≤80%RHIP68Temperature-20~60℃-30℃~160℃Essential parameter One-channel Accuracy±1% Flow rate≥0.3m/s Pipe diameterDN50~DN6000mmLiquid temperature-30℃~160℃Type of liquidWater, sea water, sewage, Acid-alkali solution, ethyl alcohol, beer, single and even liquid which can transmit sound wave, such as oil, etcSignal output1 way 4-20mA output, electric resistance 0-1K(DC24V power supply), accuracy 0.1%1 way OCT pulse output , pulse width 6-1000ms1 way relay output or frequency outputSignal input3 way 4-20mA input, can be a data collectorConnect three wire/four wire PT100 temperaturetransducer to realize heat/cooling energy measurementData interfaceInsulate RS485 serial interface, support the MODBUSPower supplyDC8-36V;AC10-30V (110V also available)Installation dimension 3. Insertion-type Ultrasonic Flow Meter Fixed mountConverters can be installed on wall surfaces or pipesLarge LCD display provides abundant informationOne-channel, two-channel, and four-channel options availableNavigation menu with four-digit capacitive key operationDurable die-cast aluminum converterEquipped with a stainless steel probe and probe columnCan connect to three-wire or four-wire Pt100 temperature transducers for heat/cooling energy measurement Working environment ConverterTransducerProtection classIP68IP68Temperature-20~60℃-30℃~160℃Essential parameter One-channelTwo-channelFour-channelAccuracy±1%±0.5%±0.5%Flow rate≥0.3m/s≥0.3m/s≥0.1m/sPipe diameterDN50~DN6000mmLiquid temperature-30℃~160℃Type of liquidWater, sea water, sewage, Acid-alkali solution, ethyl alcohol, beer, single and even liquid which can transmit sound wave, such as oil, etcSignal output1 way 4-20mA output, electric resistance 0-1K(DC24V power supply), accuracy 0.1%1 way OCT pulse output , pulse width 6-1000ms1 way relay output or frequency outputSignal input3 way 4-20mA input, can be a data collectorConnect three wire/four wire PT100 temperaturetransducer to realize heat/cooling energy measurementData interfaceInsulate RS485 serial interface, support the MODBUSPower supplyDC8-36V; AC10-30V; AC85-264V(Optional waterproof power adapter) (110V also available)Installation dimension 4. Insertion-type Ultrasonic Flow Meter Explosion proofIsolation-type explosion-proof, suitable for flammable and explosive environmentsExplosion-proof class: DIIBT5Large LCD display provides abundant informationOne-channel, two-channel, and four-channel options availableNavigation menu with four-digit key operationDurable die-cast aluminum converterEquipped with a stainless steel probe and probe columnCan connect to three-wire or four-wire Pt100 temperature transducers for heat/cooling energy measurement Working environment ConverterTransducerProtection classIP65IP68Humidity≤85%RHIP68Temperature-20~60℃-30℃~160℃Essential parameter One-channelTwo-channelFour-channelAccuracy±1%±0.5%±0.5%Flow rate≥0.3m/s≥0.3m/s≥0.1m/sPipe diameterDN50~DN6000mmLiquid temperature-30℃~160℃Type of liquidWater, sea water, sewage, Acid-alkali solution,ethyl alcohol, beer, single and even liquid which can transmit sound wave, such as oil, etc.Signal output1 way 4-20mA output, electric resistance 0-1K(DC24V power supply), accuracy 0.1%1 way OCT pulse output, pulse width 6-1000ms1 way relay output or frequency outputSignal input3 way 4-20mA input, can be a data collectorConnect three wire/four wire PT100 temperaturetransducer to realize heat/cooling energy measurementData interfaceInsulate RS485 serial interface, support the MODBUSPower supplyDC8-36V;AC10-30V;AC85-264V (110V also available)Installation dimension 5. Insertion-type Ultrasonic Flow Meter Panel MountSuitable for instrument panel mountingLarge LCD display provides abundant informationOne-channel and two-channel options availableNavigation menu with four-digit key operationShell made of ABS engineering plasticsEquipped with a stainless steel probe and probe columnCan connect to three-wire or four-wire Pt100 temperature transducers for heat/cooling energy measurementWorking environment ConverterTransducerProtection class IP68Humidity≤80%RHIP68Temperature-20~60℃-30℃~160℃Essential parameter One-channelTwo-channel Accuracy±1%±0.5% Flow rate≥0.3m/s≥0.3m/s Pipe diameterDN50~DN6000mmLiquid temperature-30℃~160℃Type of liquidWater, sea water, sewage, Acid-alkali solution,ethyl alcohol, beer, single and even liquid which can transmit sound wave, such as oil, etc.Signal output1 way 4-20mA output, electric resistance 0-1K(DC24V power supply), accuracy 0.1%1 way OCT pulse output , pulse width 6-1000ms1 way relay output or frequency outputSignal input3 way 4-20mA input, can be a data collectorConnect three wire/four wire PT100 temperaturetransducer to realize heat/cooling energy measurementData interfaceInsulate RS485 serial interface, support the MODBUSPower supplyDC8-36V;AC10-30V (110V also available)Installation dimension 6. Insertion-type Ultrasonic Flow Meter Transducer introductionStandard Insertion Transducer(ATC-1)Suitable for carbon steel pipe, stainless steel pipe, cement pipe, cast iron pipe, steel pipe, PVC pipe, or composite pipePipe wall thickness up to 20 mmMeasurement diameter range from DN50 to DN6000Temperature range: -30°C to +160°C Lengthen Insertion Transducer(ACT-2)Suitable for carbon steel pipe, stainless steel pipe, cement pipe, cast iron pipe, steel pipe, PVC pipe, or composite pipePipe wall thickness up to 70 mmMeasurement diameter range from DN50 to DN6000Temperature range: -30°C to +160°C Parallel Insertion Transducer(ATP-1)Suitable for locations with limited installation spaceCompatible with both weldable and non-weldable pipesUnlimited wall thickness with insertion depth at 1/3 of pipe diameterMeasurement diameter range from DN80 to DN6000Temperature range: -30°C to +160°CPipe hoopThe insertion transducer can be installed without welding using a pipe hoop, allowing for the installation of the insertion ultrasonic flow meter without interrupting water flow. This method is particularly suitable for installing on cement pipe, cast iron pipe, PVC, copper pipe, or composite pipe. RequestQuotation Insertion-type Ultrasonic Flow Meter First Name Last Name / Surname Position Email Phone Number Company Name Company Type - None -ManufacturerResellerGovernmentUniversity Country - Select -AfghanistanAlbaniaAlgeriaAmerican SamoaAndorraAngolaAnguillaAntarcticaAntigua & BarbudaArgentinaArmeniaArubaAscension IslandAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBermudaBhutanBoliviaBosnia & HerzegovinaBotswanaBouvet IslandBrazilBritish Indian Ocean TerritoryBritish Virgin IslandsBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCanary IslandsCape VerdeCaribbean NetherlandsCayman IslandsCentral African RepublicCeuta & MelillaChadChileChinaChristmas IslandClipperton IslandCocos (Keeling) IslandsColombiaComorosCongo - BrazzavilleCongo - KinshasaCook IslandsCosta RicaCroatiaCubaCuraçaoCyprusCzechiaCôte d’IvoireDenmarkDiego GarciaDjiboutiDominicaDominican RepublicEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEswatiniEthiopiaFalkland IslandsFaroe IslandsFijiFinlandFranceFrench GuianaFrench PolynesiaFrench Southern TerritoriesGabonGambiaGeorgiaGermanyGhanaGibraltarGreeceGreenlandGrenadaGuadeloupeGuamGuatemalaGuernseyGuineaGuinea-BissauGuyanaHaitiHeard & McDonald IslandsHondurasHong Kong SAR ChinaHungaryIcelandIndiaIndonesiaIranIraqIrelandIsle of ManIsraelItalyJamaicaJapanJerseyJordanKazakhstanKenyaKiribatiKosovoKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacao SAR ChinaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMartiniqueMauritaniaMauritiusMayotteMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMontserratMoroccoMozambiqueMyanmar (Burma)NamibiaNauruNepalNetherlandsNetherlands AntillesNew CaledoniaNew ZealandNicaraguaNigerNigeriaNiueNorfolk IslandNorthern Mariana IslandsNorth KoreaNorth MacedoniaNorwayOmanOutlying OceaniaPakistanPalauPalestinian TerritoriesPanamaPapua New GuineaParaguayPeruPhilippinesPitcairn IslandsPolandPortugalPuerto RicoQatarRomaniaRussiaRwandaRéunionSamoaSan MarinoSarkSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSint MaartenSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSouth Georgia & South Sandwich IslandsSouth KoreaSouth SudanSpainSri LankaSt. BarthélemySt. HelenaSt. Kitts & NevisSt. LuciaSt. MartinSt. Pierre & MiquelonSt. Vincent & GrenadinesSudanSurinameSvalbard & Jan MayenSwedenSwitzerlandSyriaSão Tomé & PríncipeTaiwanTajikistanTanzaniaThailandTimor-LesteTogoTokelauTongaTrinidad & TobagoTristan da CunhaTunisiaTurkmenistanTurks & Caicos IslandsTuvaluTürkiyeU.S. Outlying IslandsU.S. Virgin IslandsUgandaUkraineUnited Arab EmiratesUnited KingdomUnited StatesUruguayUzbekistanVanuatuVatican CityVenezuelaVietnamWallis & FutunaWestern SaharaYemenZambiaZimbabweÅland Islands State/Province Timeline - None -Less than one monthOne to three monthsFour to six monthsLonger than six months Message