Theory and Method
Jets differ from sprays in the energy they carry. Sprayed water arrives as a dispersed field of low-momentum droplets that a gasket lip usually deflects. A jet concentrates the same water into a coherent stream, so it delivers sustained local pressure at whatever seam, vent, or gland it lands on. IEC 60529 raises severity across numerals 5 and 6 by widening the nozzle and multiplying the flow rather than by driving supply pressure much higher.
Nozzle bore and delivery rate define the two levels. Numeral 5 uses a 6.3 mm nozzle at 12.5 L/min, while numeral 6 uses a 12.5 mm nozzle at 100 L/min, both applied at a standoff of 2.5 m to 3 m. Doubling the bore multiplies the flow eightfold, which is why the step between the two levels is far larger than the numbering suggests. Test duration runs one minute per square meter of exposed surface, with a three-minute floor.
Delivery rate is the controlled variable, and pressure follows from it. The method asks the operator to adjust supply pressure until the flow meter reads the target rate, rather than setting a pressure and accepting whatever flow results. That is why the Quali-IPX™ WJT pairs a flow meter with a precision regulator and splits the duty across two pumps. Metering 12.5 L/min on a pump sized for 100 L/min would put the setpoint at the bottom of its range, where control is poorest.