Theory and Method
Immersion tests a seal against static pressure rather than impact. Drip, spray, and jet methods all challenge an enclosure with moving water that arrives at some angle and carries momentum. Submersion removes the motion and applies a steady hydrostatic load across every surface at once, so the failure mode shifts toward gasket compression, thread engagement, and material permeability. Depth is what sets that load, since a water column exerts roughly 9.81 kPa for every meter of height.
Numeral 7 fixes the conditions. A specimen shorter than 850 mm sits with its lowest point 1,000 mm below the surface, a taller one sits with its highest point 150 mm below, and immersion runs 30 minutes with water temperature within 5 K of the specimen. The 1,200 mm vessel height covers the first case directly, since the column above the specimen base reaches the required meter with margin left over. No pressurization applies at this level, because depth alone supplies the load.
Numeral 8 leaves the conditions open. IEC 60529 requires only that they exceed the numeral 7 test and reflect the continuous immersion the product will actually see, so the manufacturer declares a depth and duration. Reproducing 30 m or 100 m of head in an open tank is impractical, so the vessel seals and pressurizes instead. A gauge pressure of 2.94 bar reproduces 30 m of water, 4.90 bar reproduces 50 m, and 9.81 bar reproduces 100 m.