Super-High-Energy Charpy V-Notch Specimens SRM must be impact tested (fractured) consecutively within the same timeframe (not on separate days) at 21°C ± 3°C. Test results and digital photographs of the fractured samples should not be emailed for evaluation. For absorbed energy, a compliant machine will produce an average value within 1.4 J or 5% of the certified energy value, whichever is greater.
Unit of Issue: Set
Unit Description: Each unit contains five Charpy V-notch specimens required for one in-house verification (self-verification). The specimens are manufactured from 9310 alloy steel.
Lot Number: SH-67
SKU: 2199
Validity: Indefinite
Safety Information
These SRMs are designed for the in-house indirect verification of Charpy testing machines equipped with 2 mm strikers, in compliance with the current ASTM E23 and ISO 148-2 standards. Testing for SRM 2199 must be conducted at 21°C ± 3°C.