Theory and Method
A geotextile filter has to do two things at once: hold soil particles back and let water through. Failure sits on either side of that balance. Fines that pass freely through the fabric wash out of the soil mass and undermine the structure, a condition known as piping. Fines that lodge in the fabric openings or pile up against its face reduce flow at the interface, which is clogging. The gradient ratio test quantifies the balance by comparing how much hydraulic head the water loses across the soil-geotextile boundary against how much it loses in the soil alone.
Manometer ports along the permeameter wall read the head at fixed elevations in the soil column. The apparatus compares the hydraulic gradient across the zone containing the geotextile and the soil immediately above it against the gradient measured in soil well away from that boundary. Dividing the first by the second yields the gradient ratio. A value near unity means the interface passes water about as readily as the soil itself, so the pairing is compatible. Values above one show that the boundary has lost permeability and fines are accumulating. Values below one point toward particle loss through the fabric.
The QualiGTX™ FPT applies flow under a constant head that the operator raises or lowers through motorized reservoir adjustment, which allows several gradient steps within one run without disturbing the specimen. Manometer tubes graduated at 1 mm resolve the small head differences that separate a compatible pairing from a marginal one. Temperature readout across the 5 °C to 50 °C range lets the analyst correct measured permeability for water viscosity, and a 6 mm support screen carries the soil column while adding negligible resistance to flow.