Ordering Information → Technical Item ↓ | Quali™ Xenon500-Plus Xenon Test Chamber |
| Xenon Lamp | 6.5 KW water cooling long arc xenon lamp |
| Light Filter | Can simulate indoor or outdoor sunshine spectrum (US-made) |
| Exposure Area | 6,500 cm2(63-65 pcs standard samples of 15cm×7cm size) |
| Monitoring Method to Irradiance | Four types:340nm,420nm,300nm~400nm,300nm~800nm Showing at the same time |
| Adjustable Irradiance | See Table B. |
| Lifetime of lamps | 2,000 hours |
| Adjustable Range of BPT | RT~110℃ |
| Adjustable Range of BST | RT~120℃ |
| Adjustable Range of Working room | RT~70℃(Dark) |
| Temperature Stability | ±1℃ |
| Temperature Uniformity | ≤2℃ |
| Temperature Deviation | ≤ 1℃ |
| Adjustable Humidity | Light:10%-80% Dark:10%-95% |
| Rotate speed of sample | 1 r/min(circle as lamp centre) |
| Spray Function | Can set spray continuous time and spray period |
| Water Demands | High purity deionized water(Conductivity<2us/cm) |
| Compressed Air | Clean,oilless compressed air with 0.5MPa pressure,Max. air supply is near 60L/min. Average air consumption is 10L/min~30L/min(Depends on testing standard) |
| Flow of Deionized Water | 0.2L/min(Add humidity or spray) |
| Power Supply | AC380V±10%,Three-phase four-wire 50Hz;Max. Current 50A,Max. Power 9.5KW |
| Overall Size | 1,220mm×1,200mm×1,970mm(L×W×H) |
| Net Weight | 500 KG |
| |
| Cabinet Material | Working room is made up of high quality stainless steel (SUS316) |
| Chamber Door | Simple door to left with filter window;silicon rubber seal the door edge |
| Sample Holder | Stainless steel material, its position in the chamber can be adjusted(up, middle or down), Sample crack rotate around the centre of lamp |
| Controller | Siemens programmable controller. LCD touch-screen |
| Way of adding humidity | Add humidity by high pressure aerosol |
| Thermometer | Heat insulate type black standard thermometer and black panel thermometer |
| Cooling System | Cooled by compressor and forced-air blast system |
| Safety Features |
| Xenon Lamp Protection | Over temperature cooling water,low flow cooling water,abnormal lamp power |
| Alarm Function | Big irradiance difference, over-temperature of BPT or BST or Working room, big error of humidity, spraying water shortage, pure water conductivity is over limits. Operator can set these values and downtime |
| Pure System Protect | Monitor the conductivity of pure water at real-time |
| Protection to Radiation | Xenon lamp will turn off automatically when opening the chamber door, in case xenon lamp radiate operator |
| Installation Environment Requirement |
| Site Requirement | Net area of installation site ≥12m2;Net height≥2.8m. Equipped with separate air condition which can ensure a 22℃~30℃ & 30%~80% environment permanently. No strong electromagnetic fields, no high concentration dust,no corrosive gas or flammable materials. |
| Power Source | 380V土10% 3-phases;50Hz;50A power source;Equipped with circuit,ground wire and air circuit breaker. |
| Air Outlet | There should be air outlet(Distance to chamber ≤1.0m,height to ground is 2.5m~2.7m, diameter should be 153mm) |
| Water Supply | Equipped with water supply pipes and valves,Supply water pressure≥2.0kg/cm2;conductivity≤120us/cm |
| Drainage | Draining pipes diameter≥ 50mm,height to ground≤10cm,distance to chamber≤0.5m |