| Model | Test Principle | Control and Automation | Description |
| QualiGTX™ GPT MN | Constant head, 250 mm maximum | Manual valve control, timer to 0.01 s | Benchtop unit with a ø50 mm clamp, 1000 mL graduated cylinder, and integrated 0 to 50 °C thermometer. Accepts specimens up to 20 mm thick. At 36 kg it suits laboratories running permeability as an occasional confirmation test. |
| QualiGTX™ GPT E | Head driven, ASTM D4491 configuration | Touchscreen, automatic timing | Entry-level cabinet configured for permittivity testing, with dissolved oxygen measurement fitted. The most direct route to a standards-referenced result for routine quality control. |
| QualiGTX™ GPT GS | Head driven, ISO 11058 configuration | Touchscreen, automatic timing | Shares the QualiGTX™ GPT E chassis, configured for velocity index testing with full dissolved oxygen specification. Choose it where reporting follows the ISO route rather than ASTM. |
| QualiGTX™ GPT V | Head driven, fixed 20 cm² test area | Touchscreen, automatic timing | Floor-standing analyzer for water resources work, with a machined aluminum alloy clamp that seals the specimen perimeter against edge leakage. Built for dam, levee, and canal filter verification. |
| QualiGTX™ GPT GW | Head driven, ø80 mm test area | Touchscreen, automatic timing | Floor-standing system with heated and cooled water held at a set point, plus a custom-configured source tank. The largest test area in the range at roughly 50 cm², which tightens repeatability on nonwovens that vary in density across a roll. |
| QualiGTX™ GPT T | Head driven, thermostatic bath | Touchscreen, temperature and DO control | Holds test water between 10 °C and 60 °C with dissolved oxygen control. Suits laboratories that study how flow capacity shifts with temperature rather than correcting for it after the run. |
| QualiGTX™ GPT M | Head driven, motorized water level | Touchscreen, powered head adjustment | Steps the head through several settings without a manual reset at each point. Multiple head readings show whether flow has left the laminar regime, which decides whether the reported coefficient is valid. |
| QualiGTX™ GPT A | Head driven, automated head sequence | Touchscreen, automated positioning and timing | Runs the full sequence with minimal operator input, with compressor cooling on the water circuit. Built for laboratories processing specimens in volume, where setup minutes accumulate across a shift. |
| QualiGTX™ GPT D | Head driven, de-aired water supply | Touchscreen, de-aeration and DO control | Top of the range, combining de-aired water, dissolved oxygen control, and temperature regulation. Removing dissolved air stops bubbles lodging in the pore structure and drifting readings downward through a run. |
| QualiGTX™ GPT GM 100 | Applied pressure, 0 to 1 MPa | 10-inch touchscreen, automatic timing | Pressure driven rather than head driven, measuring the permeability coefficient of barrier membranes across three specimens at once. Built for liner qualification, where the flow being measured sits close to zero. |