Lab vs Portable vs Online Particle Counter: Buyer's Guide
Qualitest Team

Lab vs Portable vs Online Particle Counter: Buyer's Guide

What if you could spot mechanical wear weeks before it causes equipment downtime? Keeping lubricants clean protects critical proportional valves and bearings from friction, keeping production running at peak efficiency.

At Qualitest, we supply cost-effective fluid testing hardware to help maintenance teams and test laboratories maintain dependable contamination control. This oil particle counter buyer's guide breaks down the core technical criteria to help you select the right monitoring setup for your facility.

Equipment Formats: Lab vs Portable vs Online

Solid particulate contamination accounts for up to 80% of mechanical component wear, making precise measurement vital for proactive reliability. Commercial instrumentation falls into three primary operational formats, along with modular sensing cores. The primary types of oil particle counters include:

  1. Desktop Laboratory Counters: Configured for routine offline bottle tests in controlled testing spaces, delivering fine channel-size adjustments, controlled fluid delivery rates, and integrated vacuum degassing chambers to stabilize viscous oils.
  2. Specialized Laboratory Platforms: Purpose-built for thick fluids prone to aeration, utilizing push-and-pull positive and negative pressure injection systems with syringe pumps to strip microbubbles and draw heavy samples.
  3. Portable Particle Counters: Packaged within industrial-grade carry cases featuring internal lithium battery packs, allowing field technicians to perform fast on-site screening without shipping fluid bottles to an off-site laboratory.
  4. Continuous Online and Inline Counters: Installed directly on pressurized fluid lines or lubrication circuits to deliver automated, real-time cleanliness trending and trigger immediate SCADA alarms during abnormal wear surges.
  5. OEM Sensing Cores: Compact optical modules engineered for direct mechanical installation into custom test benches, mobile diagnostic carts, or multi-parameter condition monitoring clusters.

Across our QualiOPC portfolio, all instruments utilize a semiconductor laser light source and the optical light-blocking (extinction or shading) method, with individual models configured to analyze specific fluids within the broader family of hydraulic, lubricating, transformer, gear, turbine, and engine oils, as well as aviation kerosene, organic liquids, and polymer solutions. In our assessment, optical light-blocking represents the practical gold standard for multi-channel cleanliness coding because it ties directly to established international reporting standards.

Evaluating a lab vs portable vs online particle counter comparison clarifies where each hardware format provides the strongest operational return:

ConfigurationPrimary Operational SettingElectrical Input and Fluid InterfaceKey Operational StrengthsCritical Limitations to Manage
LaboratoryDedicated analytical benchtopAC mains; offline bottles with vacuum bubble degassingHigh analytical repeatability across standardized size brackets from under 1 micrometer to over 100 micrometersTurnaround lags from transport; risk of bottle contamination
PortableField service rounds and plant floorsInternal lithium pack; bottle tests or line connectionsRapid on-site screening without courier delaysManual testing workflow; line connection safety risks
Online / InlinePressurized fluid pipeworkDC 9 V, DC 12–36 V, or selectable 110–240 VAC / 24 VDC depending on model; automated continuous streamReal-time tracking and immediate alarm triggeringAeration bubble interference and line pressure surges

Laboratory Deployments

Benchtop laboratory instruments deliver high measurement precision within climate-controlled rooms. In comprehensive oil analysis, laboratory particle counting is frequently paired with elemental techniques such as inductively coupled plasma optical emission spectrometry (ICP-OES), which resolves specific wear metals within 0.5% to 5% accuracy, while the optical counter measures the physical size distribution and total concentration of solid debris.

Commercial laboratory counters use vacuum and positive-pressure chambers or precision syringe pumps to draw fluids up to 650 cSt and eliminate bubbles, preventing aerated foam from skewing particle counts. From our perspective, if a testing facility handles diverse, uncharacterized oil grades from varied field assets, a dedicated laboratory counter remains essential.

Portable Deployments

Portable counters serve as a practical bridge between central laboratories and industrial plant floors. By bundling laser optics, microprocessors, and rechargeable battery packs into mobile kits, these tools provide field technicians with immediate cleanliness indices on-site. We believe portable units represent the most flexible option for mobile maintenance teams who need reliable contamination counts across multiple facilities without the logistical overhead of shipping samples.

Online Deployments

Online instruments prioritize automated, hands-off data streaming over manual sample handling. In bearing wear experiments, continuous online light-extinction sensors identified exponential particle growth trends and triggered automated alarms where periodic bottle sampling missed rapidly escalating failures. 

We consider online monitors the most sensible investment for critical production assets where even a few hours of undetected bearing degradation could lead to catastrophic equipment loss.

Inline vs Offline Oil Condition Monitoring

Maintenance strategies increasingly balance live machine streams against thorough laboratory extractions to optimize equipment reliability. While waiting on offline bottle samples provides detailed diagnostic characterization, multi-week turnaround intervals from off-site testing facilities risk overlooking severe mechanical failures that escalate in short order.

Evaluating inline vs offline oil condition monitoring establishes how your reliability team identifies equipment degradation:

Operational FactorInline Continuous MonitoringOffline Laboratory Analysis
Measurement FrequencyContinuous, real-time data streamingPeriodic batch runs, typically spaced 500 to 1,000 hours apart
Incipient Fault DetectionImmediate warnings on wear spikes or filter bypassDelayed detection due to sample shipment and queuing
Operational InterventionNon-invasive, continuous operational trackingManual bottle extraction; risks external dirt entry
Operating ConditionsExposed to line aeration, vibration, and temperature swingsHigh repeatability inside climate-controlled rooms

Offline Laboratory Testing

Offline testing pulls physical fluid from machine ports into clean bottles for transport to an on-site bench or an external commercial laboratory. It permits thorough fluid conditioning, including solvent dilution and vacuum degassing. 

However, we frequently point out to plant teams that relying exclusively on fixed calendar intervals (such as 500-hour or 1,000-hour schedules) introduces two significant operational hazards: you risk missing acute component failures between visits, or you discard serviceable lubricants while they retain useful operating life.

Inline Continuous Monitoring

Inline instruments measure fluid directly within active pipework, eliminating shipping delays and container contamination risks. 

They stream live data to supervisory networks and trigger automated alarms within seconds of a wear spike. That said, inline sensors operate in demanding plant conditions where pipe vibration, fluid temperature swings, and electrical interference can challenge baseline stability. 

Furthermore, simple inline counters cannot determine complex chemical degradation or distinguish metal fragments from seal fibers.

The Integrated Hybrid Model

In our opinion, debating whether inline monitoring replaces offline laboratory testing creates a false choice. Industry consensus strongly points toward a hybrid framework: deploy continuous inline sensors as operational tripwires to detect sudden contamination surges or moisture ingress, then use targeted offline laboratory testing to confirm root-cause fluid chemistry before scheduling major equipment overhauls. We consider this balanced methodology the most technically sound strategy for modern operations.

Technical Evaluation Criteria

When choosing an oil particle counter, technical teams must address physical measurement boundaries documented in lubrication engineering research.

Aeration and Degassing Protocols

Dissolved air, entrained microbubbles, and free water droplets scatter optical beams, generating false solid particle tallies in optical extinction paths. For viscous samples, laboratory conditioning techniques including vacuum degassing, solvent dilution, and ultrasonic agitation are standard engineering practices to restore measurement accuracy. 

Where anomalies persist in field samples, offline membrane microscopy per ISO 4407 provides visual confirmation. Any laboratory attempting to certify heavy gear lubricants or transformer oils without positive or negative pressure degassing runs a high risk of publishing artificially elevated cleanliness codes.

Chemical Additive Interference

Fluid chemistries containing polydimethylsiloxane silicone antifoam additives can form colloidal micelles that register as false phantom particles in light-extinction sensors. 

Direct imaging research demonstrates that optical extinction counters require baseline verification on freshly additized batches, whereas imaging systems can visually distinguish spherical antifoam droplets from jagged wear flakes. We recommend logging baseline cleanliness on fresh, unused lubricant batches before configuring critical alarm thresholds on active machinery.

Coincidence and Concentration Limits

In optical light-blocking sensors, coincidence saturation occurs when high particle concentrations cause multiple specks to pass through the optical sensing aperture simultaneously, resulting in count distortion and false sizing. 

Cleanliness standards like ISO 4406 report contamination at three cumulative size thresholds: 4 µm(c), 6 µm(c), and 14 µm(c), where each step up in code number represents a doubling of the particle concentration per milliliter (for example, Code 18 represents 1,300 to 2,500 particles/mL, while Code 19 represents 2,500 to 5,000 particles/mL). Because each code tier doubles the concentration, a statistical margin of error of plus or minus 50% in absolute counts corresponds to half an ISO code level under ISO 11171 calibration standards.

While academic wear studies observe complete optical saturation at contamination levels exceeding ISO 4406 codes of 24/23/14 (greater than 80,000 particles/mL), commercial instruments operate under defined coincidence limits, such as the 12,000 to 40,000 particles/mL threshold specified across standard QualiOPC models. 

Sizing results can also differ between light-extinction calculations and boundary imaging when evaluating heavily degraded, non-spherical wear debris. Expecting linear counting accuracy in heavily neglected, visibly sludged systems without prior fluid dilution is unrealistic.

Flow Metering and Pressure Limits

Early inline counters depended on external metering pumps to maintain steady flow rates through the measurement cell. Modern inline designs utilize internal flow monitoring paired with dynamic pulse algorithms or volume compensation to calculate contamination indices accurately across fluctuating flow conditions. 

In all inline installations, managing system differential pressure, mounting location, and mechanical vibration is critical for measurement stability. We believe integrated volume compensation is an indispensable feature for inline sensors, because operating machinery lines rarely run at perfectly constant flow velocities.

Alternative Sensing Technologies

In academic literature, researchers investigate adjacent sensing technologies for specialized diagnostic tasks. These include inductive coils that resolve metallic fragments while remaining insensitive to silicates, multi-parameter impedance circuits for sorting mixed contaminants, microwave cavity resonators that track overall fluid contamination, and acoustic micro-vibrations across membranes to redistribute particles by size. 

While these academic projects offer value for specialized forensic metallurgical studies, calibrated optical light extinction remains the established commercial foundation for standard cleanliness coding across industrial oils.

Application Profiles

To assist your equipment evaluation, review these three primary buyer profiles based on operational environment.

Profile 1: Analytical Laboratories

Managers of commercial fluid testing laboratories or internal plant oil laboratories routinely process high volumes of diverse samples, ranging from light turbine lubricants to viscous gear formulations up to 650 cSt. Their primary operational duties require high sample throughput, tight repeatability, and formal cleanliness certificates aligned with ISO 4406, NAS 1638, or SAE AS4059.

For these operations, we consider the QualiOPC 1000 the most sensible desktop choice, utilizing an integrated positive and vacuum chamber (-0.08 MPa vacuum) to degas aerated fluids. When analytical duties regularly involve highly aerated, thick lubricants requiring positive and negative syringe delivery or multi-user access security, we believe the QualiOPC VES platform provides the necessary mechanical capability with its expanded 8 to 64 channel flexibility, reporting cleanliness according to standards such as NAS 1638, SAE AS4059F, ISO 11171, and GOST 17216.

Profile 2: Mobile Field Service

Field service engineers and mobile plant reliability specialists audit hydraulic systems across construction sites, surface mines, marine vessels, and rail depots. Their duties demand durable portability, internal battery runtime, and rapid test cycles without relying on fragile laboratory glassware or off-site sample shipping.

In this field setting, the QualiOPC 400 delivers portable testing in an embedded carry-case format, supporting offline bottle testing and optional direct line sampling. When moisture tracking is equally critical, such as monitoring water-cooled gearboxes or outdoor hydraulic reservoirs, we view the QualiOPC 400H as the superior investment because its integrated water-content measurement (10 ppm to 500 ppm) eliminates the operational hassle of carrying a secondary moisture tester. Both portable units connect to lines up to 40 MPa when fitted with an optional pressure reducer.

Profile 3: Continuous Plant Monitoring

Plant automation specialists and site reliability engineers oversee critical, non-stop production assets such as wind turbine gearboxes, primary steel mill hydraulics, and automated assembly presses. Their goal is zero unplanned downtime, requiring automated round-the-clock trending, early tripwire alerts for sudden component wear, and direct communication with plant SCADA and PLC architectures.

For permanent line installations, we view the QualiOPC-OL2 as the premier inline compact solution, rated up to 10 MPa standard (optional up to 70 MPa) and encased in an IP54 aluminium body with Ethernet MQTT/Modbus TCP, RS485, and 4 to 20 mA interfaces. Alternatively, the QualiOPC 500 provides continuous line surveillance with an integrated 7-inch Android display for local operator review and automated monitoring intervals from 1 second to 24 hours.

QualiOPC Specification Overview

Our QualiOPC series provides targeted fluid contamination monitoring across laboratory, field, and inline environments:

ModelFormatParticle Size RangeChannelsPrimary Application Fit
QualiOPC 1000Desktop Laboratory0.8–500 μm32 channelsHigh-precision routine laboratory analysis
QualiOPC VESLaboratory Platform0.8–600 μm8–64 channelsHigh-viscosity and aerated fluid analysis
QualiOPC 400Portable Carry-Case1–500 μm32 channelsField service diagnostics and mobile auditing
QualiOPC 400HPortable Carry-Case1–500 μm32 channelsField testing with integrated moisture detection
QualiOPC 500Online Display Unit1–500 μm32 channelsContinuous line monitoring with Android display
QualiOPC-OL2Inline Compact Unit1–100 μm16 channelsPressurized lines and plant SCADA integration
QualiOPC 60Modular Sensor Core1–500 μmSystem-dependentIntegration into custom diagnostic packages

Instrument Portfolio Breakdown

QualiOPC 1000 (Desktop)

The QualiOPC 1000 serves as our core laboratory benchtop instrument for routine particle contamination testing. It operates across a detection range of 0.8–500 μm, with standardized calibration ranges of 1–100 μm per ISO 4402 or 4–70 μm(c) per ISO 11171, and sensitivity of 1 μm (ISO 4402) or 4 μm(c). 

The system features 32 channels configurable in 0.01 μm increments and handles sample volumes of 0.3–100 mL (0.1 mL interval) with a volume relative error better than ±0.5%. Its controlled sample chamber handles a maximum positive pressure of 0.8 MPa and maximum vacuum of -0.08 MPa, allowing operators to degas samples and process viscosities up to <650 cSt. 

Built with an internal Windows industrial computer, it outputs results via an internal database, integrated thermal printer, and USB export. Supported cleanliness standards include ISO 4406, ISO 11171, ISO 4402, NAS 1638, SAE AS4059E/F/FI, SAE ARP749D, GOST 17216, and AETF1A.

QualiOPC VES (High-Viscosity Lab)

Engineered specifically for challenging fluid matrices and degassing jobs, the QualiOPC VES covers a particle size range of 0.8–600 μm with high sensitivity of 0.8 μm (ISO 4402) / 3 μm (ISO 11171) and 8 to 64 optional channels. It uses a high-pressure syringe pump with positive and negative pressure injection for microbubble elimination, an integrated pressure sensor, and internal air purification, processing fluids up to ≤650 cSt. 

For viscous batches up to 400 cSt, the optional PC-VES external pressure sampler (290 × 190 × 270 mm, 6.5 kg) provides a miniature air compressor, transparent viewing window, and 0–0.5 MPa operating pressure. The instrument features a 7-inch color touchscreen, account management for more than five accounts, RS232, RS485, and real-time cleaning monitoring with automatic cutoff when the target fluid baseline is reached. Supported standards include ISO 11171, ISO 4402, NAS 1638, SAE AS4059F, and GOST 17216.

QualiOPC 400 (Portable)

The QualiOPC 400 packages optical detection into an embedded structural carry case built for field durability. Powered by an internal lithium battery alongside a 110–240 V AC input, it operates across 32 channels (0.1 μm intervals) spanning 1–500 μm with a counting accuracy of ±10% and sample volumes from 10–100 mL. Flow rates for detection and cleaning are adjustable between 5 and 60 mL/min (default 25 mL/min). 

The unit supports offline bottle tests as well as optional online sampling (0.1–0.6 MPa standard, or up to 40 MPa with an optional pressure-reducing device; online viscosity <100 cSt). Windows-based industrial controls manage the onboard database, built-in thermal printer, and USB export. Built-in cleanliness coding includes ISO 4406, ISO 11171, ISO 4402, NAS 1638, SAE AS4059E/F, SAE 749D, ROCT 17216, JTS-005, and AETF1A.

QualiOPC 400H (Portable with Water Sensor)

Housed in a 380 × 310 × 205 mm carry case weighing 8.6 kg, the QualiOPC 400H integrates direct oil water-content measurement alongside 32-channel particulate counting (1–500 μm). Its moisture sensor measures dissolved and free water across 10 ppm–500 ppm, with an accuracy of ±5 ppm from 10–100 ppm and better than ±10% from 100–500 ppm. 

It operates in offline or online modes (online viscosity <100 cSt, with an optional positive-pressure sampler for higher viscosities) and connects to lines up to 40 MPa via the optional pressure reducer. Data management, electrical options, and reporting standards match the QualiOPC 400 platform, providing field teams with combined particulate and water screening in a single mobile device.

QualiOPC 500 (Online Display)

The QualiOPC 500 is an online monitoring unit equipped with an integrated 7-inch industrial display running an Android operating system. It provides continuous 32-channel particle sizing (1 μm to 500 μm) with user-selectable monitoring intervals from 1 second to 24 hours. The unit handles online line pressures from 0.1 to 0.6 MPa (expandable to 40 MPa with the optional pressure-reducing device) and weighs 5.5 kg with dimensions of 380 × 280 × 170 mm. 

In addition to local trend graphing and built-in printing, the unit provides RS485 or RS232 industrial outputs and supports an optional moisture sensor module. It calculates standard cleanliness codes for ISO 4406, NAS 1638, and SAE AS4059, allowing plant operators to monitor pressurized lubrication circuits without external computers.

QualiOPC-OL2 (Inline Compact)

Constructed from high-strength aluminium alloy with an IP54 ingress protection rating, the QualiOPC-OL2 is an inline monitor built for continuous operation in pressurized hydraulic and lubrication circuits. It measures across 16 simultaneous channels (1 µm – 100 µm) split into ISO 4402 / NAS 1638 series (1, 2, 5, 10, 15, 25, 50, 100 µm) and ISO 11171 series (4, 4.6, 6, 10, 14, 21, 38, 70 µm(c)). Standard operating pressure covers 0.2 – 10 MPa, with an optional high-pressure rating up to 70 MPa. 

It operates with low electrical consumption (≤ 8 W typical) and handles flow rates from 10 – 100 mL/min using real-time flow monitoring with volume compensation for 10 mL counting volumes. The unit features a 3.5-inch color TFT-LCD screen, onboard storage for ≥ 100,000 records, local alarm relays, an optional water activity (Aw) sensor, and an extensive connectivity suite: Ethernet (10/100 Mbps, MQTT / Modbus TCP), RS485 (Modbus RTU), RS232, isolated 4–20 mA analog output, USB, and optional Bluetooth 5.0.

QualiOPC 60 (OEM Sensor)

The QualiOPC 60 is a standalone optical light-blocking sensing core built for mechanical integration into custom fluid monitoring systems, machinery manifolds, or mobile diagnostic carts. Featuring a cylindrical body (214 mm length, 115 mm maximum height, 52 mm head diameter, and 46 mm tail diameter), it mounts via a movable fixture with M4 screws. 

It detects particles from 1 μm to 500 μm with sensitivity of 1 μm (ISO 4402) or 4 μm(c) / 4 μm (ISO 11171) and flow rates between 5 and 60 mL/min (default 25 mL/min). Calibrated in alignment with ISO 4402 and ISO 11171, it provides the core optical sensing signals required by host counters and diagnostic processors to determine ISO 4406, NAS 1638, ROCT 17216, and SAE AS4059 cleanliness codes.

Cost of Ownership and Economic Considerations

When evaluating an oil particle counter purchase, maintenance managers must weigh capital investment against ongoing operational expenses. Relying solely on outsourced commercial laboratories incurs recurring per-sample testing fees, sample shipping expenses, and administrative overhead, alongside the operational risk of waiting days or weeks for lab reports. 

An in-house desktop or portable counter requires an initial equipment investment, but the marginal cost per test drops to routine cleaning solvent and flushing cycles, making in-house testing increasingly cost-effective as monthly sample volumes expand.

For continuous online and inline monitoring, initial equipment costs are accompanied by installation requirements, including mechanical line integration, pressure-reducing devices where system pressures exceed 0.6 MPa, and control network wiring. However, for critical machinery such as wind turbine gearboxes or primary production lines, these upfront costs are readily justified by real-time failure prevention, where avoiding a single unplanned outage can offset the entire monitoring investment.

Choosing an Oil Particle Counter with Qualitest

Protecting production equipment from premature wear begins with dependable fluid cleanliness data. Whether your facility requires the analytical accuracy of a desktop counter, the flexibility of a battery-powered field unit, or continuous inline surveillance, Qualitest delivers cost-effective testing instruments engineered for demanding industrial environments.

Contact our technical sales team today to discuss your fluid monitoring specifications, evaluate instrument configurations, and request a quote on any model in our QualiOPC lineup.


References (Click to expand)
  • Chen, C., Yang, L.-J., Zhao, W., Chen, Z., Yu, X., Li, Y., & Liao, R.-J. (2026). Study on Impurity Particle Detection in Transformer Oil Based on Microflow Imaging Method. High Voltage.
  • Conway, N., Giebeler, C., & Wiesent, B. (2022). How to get Lab Equivalent Oil Analysis 24/7. Tribologie und Schmierungstechnik.
  • Erdani, Y., & Gumadi, R. A. (2024). Implementation of Automatic Particle Counter for Hydraulic Oil Condition Monitoring. Jurnal Otomasi Kontrol dan Instrumentasi.
  • Krogsøe, K., Eriksen, R., & Henneberg, M. (2021a). Performance of a light extinction based wear particle counter under various contamination levels. Sensors and Actuators A-physical, 331, 112956.
  • Krogsøe, K., Henneberg, M., & Eriksen, R. (2018). Model of a Light Extinction Sensor for Assessing Wear Particle Distribution in a Lubricated Oil System. Sensors (Basel, Switzerland), 18.
  • Michael, P. W., Wanke, T., & McCambridge, M. (2007). Additive and Base Oil Effects in Automatic Particle Counters. Journal of Astm International, 4, 1-7.
  • Ng, F., Harding, J., & Glass, J. (2017). Improving hydraulic excavator performance through in line hydraulic oil contamination monitoring. Mechanical Systems and Signal Processing, 83, 176-193.
  • Tič, V., & Lovrec, D. (2019). On-line Condition Monitoring of Hydraulic Oils: Understanding the Results. Proceedings on Engineering Sciences.
  • Wang, Y., Zhang, M.-J., & Liu, D.-F. (2011). A Compact on-Line Particle Counter Sensor for Hydraulic Oil Contamination Detection. Applied Mechanics and Materials, 130-134, 4198-4201.
  • Westin, P.-O., Marklund, P., & Sandström, J. (2013). Wear detection by monitoring hydraulic oil contamination: an experimental comparison between on-line and off-line measurements.

FAQ (Frequently Asked Questions)

What is the coincidence error limit for QualiOPC particle counters and how should high-concentration fluids be handled?

The coincidence error limit for optical light-blocking detection across the QualiOPC 1000, 400, 400H, 500, and 60 sensor is 12,000 to 40,000 particles per milliliter. When fluid contamination exceeds this threshold, multiple small particles pass through the optical sensing aperture simultaneously, causing the detector to register overlapping particles as a single larger particle. In laboratory environments, operators handling viscous fluids up to 650 cSt utilize the vacuum degassing chamber on the QualiOPC 1000 to eliminate bubbles, or use the QualiOPC VES platform, which explicitly supports fluid heating and solvent dilution protocols to manage heavy contamination and high viscosity.

How can QualiOPC particle counters be connected to high-pressure lines exceeding standard pressure ratings?

Connecting QualiOPC portable or online instruments to hydraulic circuits above standard line pressures requires using an optional pressure-reducing device or choosing the high-pressure configuration of the QualiOPC-OL2. The QualiOPC 400, QualiOPC 400H, and QualiOPC 500 operate under a standard line pressure of 0.1 to 0.6 MPa, but can sample from circuits up to 40 MPa when fitted with an optional pressure-reducing accessory. For continuous inline monitoring in high-pressure circuits, the QualiOPC-OL2 operates at 0.2 to 10 MPa standard and can be ordered with an optional pressure rating up to 70 MPa.

How do QualiOPC systems regulate cleaning and flushing cycles between different oil samples?

Sensor cleaning speeds on the QualiOPC 1000, 400, 400H, 500, and 60 sensor are user-configurable from 5 to 60 mL per minute, while the QualiOPC VES laboratory platform automates cleaning cycles through real-time optical monitoring. The QualiOPC 1000 operates with a default cleaning and detection speed of 15 mL per minute, while the QualiOPC 400, 400H, 500, and 60 sensor operate with a default speed of 25 mL per minute. On the QualiOPC VES laboratory platform, real-time cleaning monitoring tracks particle concentrations continuously and automatically stops the cleaning process once the sample cell reaches the targeted baseline cleanliness.

Which calibration curves and particle sizing standards are supported across the QualiOPC series?

QualiOPC instruments align with ISO 4402 and ISO 11171 calibration standards, with specific models (such as the QualiOPC 1000, 400, 400H, and 500) supporting selectable calibration curves for ACFTD, ISOMTD, polystyrene latex spheres, and GOST reference materials. Calibration sensitivity is aligned with 1 micrometer under ISO 4402 and 4 micrometers(c) under ISO 11171 across models including the QualiOPC 1000, 400, 400H, 500, and OL2, while the QualiOPC VES provides sensitivities of 0.8 micrometers under ISO 4402 and 3 micrometers under ISO 11171. The QualiOPC-OL2 also includes an onboard ISO 4402 and ISO 11171 calibration wizard with documented traceability to NIST AC Fine Test Dust reference material.

What moisture and water measurement options are available across the QualiOPC lineup?

The QualiOPC 400H includes built-in oil water-content measurement from 10 ppm to 500 ppm, while the QualiOPC 500, QualiOPC VES, and QualiOPC-OL2 provide optional moisture sensor integrations. On the QualiOPC 400H, the integrated water-content sensor provides an accuracy of plus or minus 5 ppm between 10 and 100 ppm, and better than plus or minus 10 percent between 100 and 500 ppm. For continuous inline monitoring, the QualiOPC-OL2 supports an optional water activity sensor, and the QualiOPC VES supports an optional integrated module that measures viscosity, moisture content, and temperature alongside particle counts.